Quick Answer
When comparing supplier data, first confirm the metric, the unit, the material or assembly it describes, and the test or calculation conditions. The same thickness or a numerically larger R-value does not by itself prove that one finished panel performs better than another. A core R-value and a panel U-value describe different things, and they cannot be compared directly without aligning the scope and conditions behind each figure.
What Do Thermal Conductivity, R-Value and U-Value Describe?
Thermal conductivity, thermal resistance and thermal transmittance are related but distinct quantities. The table below summarises what each one describes and its SI unit.
| Quantity | Symbol | What it describes | SI unit |
|---|---|---|---|
| Thermal conductivity | λ or k | The heat conduction property of a material under stated conditions. | W/(m·K) |
| Thermal resistance | R | The temperature difference divided by heat flow rate per unit area for the specified layer or assembly. | m²·K/W |
| Thermal transmittance | U | The heat transfer coefficient of a specified assembly: heat flow rate per unit area and per unit temperature difference under stated boundary conditions. | W/(m²·K) |
Under comparable conditions, a lower λ means lower conductivity for that material, a higher R means greater resistance for that layer or assembly, and a lower U means lower transmittance for that assembly. Compare values with a matching assessment scope and conditions. The products themselves can have different materials or thicknesses.
R can describe a material layer, a panel core or an assembly. U can describe a panel, a roof or wall assembly, or another defined construction. The supporting document defines the scope. Suppliers may use the label “R-value” for either SI or US customary units, so read the accompanying unit.
For an overview of core options, see our guide to sandwich panel materials.
What Does the Thermal Data Cover?
Check Units Before Comparing Numbers
SI thermal resistance is expressed in m²·K/W. US customary thermal resistance is often expressed in h·ft²·°F/Btu. The two are not numerically interchangeable.
For example, if a source document explicitly states a US R-value of R-20 with units of h·ft²·°F/Btu, the conversion to SI is:
RSI = RUS × 0.1761102
20 × 0.1761102 ≈ 3.52 m²·K/W
The conversion changes the unit only. It does not change what is being evaluated. If the original figure described a core material, the converted figure still describes that core material. If the original figure described an assembly, the converted figure still describes that assembly.
An “R-20” without a stated unit should not be automatically assumed to be a US R-value. The source document should state the unit system, and the reviewer should confirm it before any comparison.
Why a Core Calculation Is Not Automatically a Panel U-Value
For steady, one-dimensional heat flow through a hypothetical homogeneous layer, thermal resistance can be calculated as Rlayer = d / λ. Consider this example:
- Layer thickness: 100 mm = 0.100 m.
- Assumed thermal conductivity: 0.025 W/(m·K).
- Rlayer = d / λ = 0.100 / 0.025 = 4.00 m²·K/W.
Here, d is the material layer thickness, not the overall depth of a profiled panel. The figures are hypothetical, not Bingfa product specifications or standard values for a core material category.
This result describes the hypothetical layer only. A finished-panel assessment must also define the relevant surface conditions and the construction included. The relationship U = 1 / Rtotal requires total resistance and U to refer to the same construction, assessment area and boundary conditions, using compatible units. Taking the reciprocal of a core-layer resistance does not establish a finished-panel U-value.
A Practical Supplier Comparison
Consider a hypothetical procurement scenario. Supplier A provides a core thermal resistance of US R-20. Supplier B provides a U-value for a specific panel type in W/(m²·K), but the document scope and conditions still need to be verified.
| Supplier | What is currently known | Key missing information | What to request |
|---|---|---|---|
| Supplier A | Core thermal resistance stated as US R-20 | Finished-panel data for the quoted panel type, thickness and assembly | Panel-level thermal data for the quoted configuration, with units, conditions and a document reference |
| Supplier B | Panel U-value stated in W/(m²·K) | The exact panel model, evaluation method, conditions and included components | The model and configuration, calculation or test basis, boundary conditions, and treatment of joints and fasteners |
The available information is not yet sufficient to rank the finished panels. Obtain data for both quoted configurations using a comparable metric, units, assessment scope and conditions, then compare the documented performance against the project requirement. The core materials or thicknesses can differ if each configuration is clearly identified. More complete paperwork alone does not establish better thermal performance.
Have thermal requirements or supplier data for a planned roof or wall? Share them with your proposed panel type and drawings to discuss the available documentation and supply scope.
Discuss Your Panel Insulation Requirements
What to Record Before Comparing Quotations
Before comparing quotations, record the following information for each supplier.
| Record item | What to capture |
|---|---|
| Product and application | Product model, roof or wall application, thickness definition |
| Metric and value | Metric name, numerical value and complete unit |
| What is evaluated | Whether the value describes the core, the panel or another defined assembly |
| Document reference | File name, date, and the stated test or calculation basis |
| Conditions | Temperature, relevant moisture conditions, declared or design value, and any ageing statement |
| Included components | Whether joints, fasteners or other construction factors are included |
Some product documents include standard joints in the U-value, while certain fasteners or project-specific interfaces may be handled separately. Record what is included and what requires separate consideration; this helps the project team avoid omissions or double-counting. Keep qualifiers such as “declared”, “design” and any ageing statement with the value.
Not all valid U-values must come from the same test method. The calculation or test scope stated in one manufacturer’s document is not automatically a universal industry rule. A U-value alone also does not prove airtightness, absence of condensation, or whole-building energy performance. For broader insulation system context, see steel building insulation systems.
Preparing a Panel Supply Inquiry
To discuss panel supply with Bingfa, send the project location and use, roof or wall application, proposed panel type, available drawings and any specified thermal requirements or existing supplier data. These details help us discuss the available product documentation and define the supply scope. Include the project’s thermal criteria and required supporting documents with the inquiry.
Organise quantities by panel type and length alongside the performance requirements. Our guide to sandwich panel quantity calculation explains how to prepare roof and wall schedules.
Frequently Asked Questions
Can I compare panels by thickness alone?
No. Thickness affects thermal resistance, but the panel’s overall thermal performance also depends on the core material, the facings, the joints and the boundary conditions. A thicker panel is not automatically better in every comparison. Compare the complete documented configuration, not only the thickness.
Is a core R-value the same as a panel-system rating?
A core R-value describes the specified core layer. A reported panel or system value applies to the construction and conditions defined in its supporting document, which may include other components or boundary effects. Check that scope before using it in a supplier comparison.
Can I convert any R-value directly into a U-value?
Not directly. The relationship U = 1 / Rtotal applies only when the assembly, evaluation scope, units and boundary conditions are compatible. A core R-value cannot be converted directly into a panel U-value without accounting for the complete assembly.
What documents should I request before comparing quotations?
Request the product data sheet for the quoted panel type, including the metric, value, unit, evaluation scope, document date, test or calculation basis, conditions, and whether joints and fasteners are included. Also request confirmation of the model and configuration the data applies to.
For a panel supply inquiry, send the project location, roof or wall application, proposed panel type, drawings and available thermal requirements.
Discuss Your Panel Insulation Requirements
Technical References
- NIST SP 811, Appendix B.8 — unit conversion factors.
- ISO 9869-1:2014 — public abstract on thermal resistance and transmittance.
- ROCKWOOL — thermal resistance and layer calculations (Polish).
- Ruukki — Linear Thermal Transmittance Values for SPA Panel Details (June 2020; manufacturer-specific scope).
- Kingspan — Design Guide for Flat Roof Products (March 2026, Hungary edition; thermal design section).